Help Videos for WPM Heat Pump Controller Settings

Setting the comfort, ECO and hot water mode

This series of videos wordlessly demonstrates various settings of the WPM heat pump controller used with the Stiebel Eltron WPL A2W Premium cold climate heat pump.

Set the operating programs of your WPL heat pump on the WPM controller: comfort, ECO and DHW modes.

Save energy and costs with operating programs: At the end of the heating season, activate the hot water mode on your heat pump so that it only provides hot water during summer operation. Are you going on vacation? Remember to turn on the ECO mode of your heat pump! Our help video shows you how.

Set operating modes: Explained step-by-step

1. After pressing the menu button for 3 seconds, the controller can be unlocked and settings can be adjusted.

2. In the lower area of the start view of the controller, the different operating modes can be viewed and changed via the rotary control.

3. Turn the control dial until you have reached the desired operating mode.

4. The selected operating mode is activated by confirming with the "OK" key.

Set operating modes: Tips for comfort, ECO and DHW operation

1. Comfort mode: We recommend this operating mode if you live in a low-energy house and no temperature reduction is necessary. The heating circuit (HK) is kept at a constant comfort temperature (heating circuit 1 and heating circuit 2). Hot water is prepared according to the time program.

2. ECO operation: Energy-saving tip during your weekend or vacation! The heating circuit is kept at a constant ECO temperature (heating circuit 1 and heating circuit 2). Hot water is prepared according to the time program.

3. DHW mode: The heating period is over and you only need hot water in your home (summer mode). In this operating program, the hot water is heated according to the time program. If a time program is active, the water in the hot water tank is heated to the comfort setpoint. During the other times, the water is heated to the ECO setpoint. The frost protection function is activated for heating operation.

Set room temperature

You can set your comfortable temperature quickly and easily on the WPM controller of your WPL heat pump. Energy-saving tip for your heat pump: Use your individual heating program to heat only when you really need it. In ECO mode, a lower room temperature is set compared to comfort mode. This saves energy costs! For example, you can set the ECO temperature during the day when you are not at home, or at night - during these periods the room temperature is lowered to the value you set. Our help videos show you how to do this.

Set room temperature: Explained step-by-step

1. After pressing the menu button for 3 seconds, the controller can be unlocked and settings can be made.

2. The menu item "Settings" then takes you to the submenu where you can set the temperatures for your various heating circuits under the heading "Heating" (depending on the system configuration, up to 2 heating circuits are available).

3. Now set the comfort temperature and the eco temperature here and confirm your entry with "OK".

4. You can then use the "MENU" key to go back to the previous menu levels until you have reached the start view again.

The current ACTUAL room temperature for your heating circuits is displayed on the Start screen, for example, under the item "ACTUAL TEMPERATR HK 1". A change in the room setpoint temperature causes a parallel shift of the heating curve. The higher the room setpoint temperature is set, the higher the energy costs you can expect.

Set heating program

In the HEATING PROGRAM menu item, you can define for the different heating circuits when and how often the unit is to heat with the comfort setpoint (room temperature). At other times, the unit heats with the lower ECO setpoint. You have the option of setting your heating for:

• each individual day of the week (Monday - Sunday)
• Monday - Friday (Mon - Fri)
• Saturday and Sunday (Sat - Sun)
• the whole week (Mon - Sun)

You can now set three switching time pairs per day. The three switching time pairs are listed in the display to the right of the clock. A switching time pair consists of the start time and the end time at which the unit returns to the previous state. The time is entered with a step duration of 15 minutes.

Setting the heating program: Explained step-by-step

1. After pressing the menu button for 3 seconds, the controller unlocks.

2. Via "Programs" you reach the submenu where you set the time periods for your different heating circuits in "Heating program". Depending on the system configuration, up to 2 heating circuits are available.

3. Now select individual weekdays or fall back on our predefined settings. To fall back on the latter, turn the operating circle until you have passed the individual selection of weekdays. Confirm your selection with the "OK" button.

4. Set the start and end time for the switching time you have selected via the rotary control at which the comfort heating mode is to be active and confirm your entry with "OK".

Press the "MENU" button to return to the start view. Unfortunately, a setting beyond midnight (00:00) is not possible - you must set two switching times for this application.

Set hot water temperature

You can set your hot water comfort temperature quickly and easily on the controller of your WPL heat pump.

Setting the water temperature: Explained step-by-step

1. After pressing the menu button for 3 seconds, unlock the controller unlocked

2. You can access the "DHW" submenu via "Settings".

3. To set your desired hot water temperature, select "DHW temperatures" in the 4th menu level.

4. Now set the comfort temperature and the ECO temperature for your DHW preparation. Confirm your entries with "OK".

5. Click on "Menu" to return to the standard view.

The current DHW temperature is displayed on the start screen under the item "ACTUAL WW TEMPERATURE".

Notes

• The higher the DHW setpoint temperature is set, the higher the energy costs you can expect.

• If the desired/set DHW temperature is not reached, please contact your installer.

Please note that anti-legionella treatment may be required if hot water is drawn irregularly. You will find information on this in our operating and installation instructions. If you have any further questions, please contact Stiebel Eltron.

Set hot water program

Energy-saving tip for your heat pump: Use your individual DHW program to only use high-temperature water when you really need it. In ECO mode, a lower DHW temperature is defined than in comfort mode. This saves energy costs!

Save costs and energy with your individual hot water program

In the "DHW program", you define the times during which hot water is to be prepared with the comfort setpoint. During the other times, the hot water is prepared with the ECO setpoint. What does this mean exactly? In ECO mode, a lower DHW temperature is defined than in Comfort mode and can therefore always be used when there is no need for hot water. This saves energy and costs!

You have the option of setting the water heating for:

• each individual day of the week (Mon - Sun)
• Monday - Friday (Mon - Fri)
• Saturday and Sunday (Sat - Sun)
• the whole week (Mon - Sun)

For each of these options, you can set three switching time pairs per day. The time is entered with a step duration of 15 minutes.

Setting the DHW program: Explained step-by-step

1. After pressing the menu button for 3 seconds, unlock the controller.

2. You can access the "DHW program" submenu via "Programs".

3. Select individual days of the week or access our predefined settings. To fall back on our predefined settings, turn the operating circle until you have exceeded the individual selection of all weekdays. Confirm your selection with the "OK" button.

4. After enabling the setting option, set your desired START and END time for the DHW program by means of the "OK test" using the rotary control.

5. After you have selected the START time, confirm this by pressing "OK"-.

6. Use the rotary control to navigate to the END time, unlock with "OK" and set the END time.

Press the menu button to return to the standard view. The time switching pairs should be selected so that complete heating of the water tank is possible between switching on and off (at least 3 hours). A setting beyond midnight (00:00) is unfortunately not possible - you must set two switching times for this application.

Set cooling function

Our help video shows you how to activate or deactivate this function on your heat pump.

Setting the cooling function: Explained step-by-step

1. After pressing the menu button for 3 seconds, the controller unlocks itself

2. Via "Settings" you reach the submenu where you can activate or deactivate your cooling function under "Cooling".

3. To make the setting here, enter the code "1000". Use the rotary control to set the digits, confirm with "OK" and jump to the next digit.

4. The cooling function is switched on or off via the rotary control, confirm your selection with "OK".

5. Click on "Menu" to return to the standard view.

When the cooling function is activated, the symbol of a "snowflake" appears on the start screen. Your heat pump is now in cooling mode and cools your home. The heat pump manager WPM of your heat pump must be in "SUMMER OPERATION" mode for the heat pump to start cooling operation. If the cooling parameters are not visible or the cooling function cannot be activated properly, please contact your installer. They will check the necessary components for cooling operation and the necessary controller settings.

Reset

Reset: the first step to rectifying a system malfunction

Is your WPL heat pump reporting a fault or error on the WPM controller? Tip: Press the reset button. Activating the reset button resets the error that has occurred. The compressor starts up again. The error remains stored in the error list. Sometimes the heat pump can be restarted just by doing this. Our help video shows you how to do it!

Set the reset of the heat pump: Explained step-by-step

1. After pressing the menu button for 3 seconds, unlock the controller.

2. You can access the "Reset" submenu via the "Commissioning" menu item.

3. Select "Heat pump" in the reset menu. The default setting is "OFF". To be able to make the setting here, enter the code "1000". Select the individual digits via the rotary control, confirm with "OK" and then jump to the next digit.

4. The reset function is switched on or off via the rotary control. Confirm with "OK”.

5. The setting is "ON". The controller reset is carried out.

6. After the controller has been reset, the setting in the menu overview jumps back to "OFF".

7. Use the menu button to go back to the previous menu levels until you reach the standard view again.

Read out error list

Is your WPL heat pump displaying an error message on the WPM controller?

In the event of an error message, specifying the error(s) or the software statuses can be very helpful for your installer or our technical support staff. The error list gives you an overview of the errors recently registered by the unit. The error list contains up to 50 error messages. Our help video shows you how to read out the error list of your WPL heat pump.

Read out error list: Explained step-by-step

1. After pressing the menu button for 3 seconds, unlock the controller.

2. Select "Diagnosis", scroll down to the "Notification List".

3. The small number next to the name of the menu item "Notification List" already shows you how many error messages have been logged.

4. The error messages are displayed in a table. In addition to the error code, the date and time when the error message was logged are listed. Pass this information on to your installer or our factory customer service.

5. Use the menu button to go back until you reach the standard view again.

Please always state the error code(s) to your installer or the factory customer service while troubleshooting!

Activating emergency mode

No more heating or hot water?

Using the emergency operation of your WPL heat pump, you have the possibility to temporarily fix the malfunction for a certain time by means of a backup heat source, if installed. If your heat pump has an electric heating element, you can find the instructions for activating emergency operation here.

Set emergency operation: Explained step-by-step

1. After pressing the menu button for 3 seconds, the controller unlocks.

2. In the lower section of the start view of the controller, you can see the different operating modes and change them using the rotary control.

3. Turn the control knob until you have reached the emergency mode.

4. The selected operating mode is activated by confirming with the "OK" key.

5. You have selected the emergency mode? The corresponding symbol of the electric emergency/auxiliary heating is displayed on the start view of the controller.

6. Your heat pump is in emergency mode. Now contact your installer to fix the fault.

Please note that the emergency operation only heats using the backup heat source and should not be used permanently. Emergency operation is only for temporary purposes and is the responsibility of the system owner. Contact Stiebel Eltron or your specialist installer to fix the fault.