Master Panel Valve, Electric

product-bullets-and-image

product-body

HydroShark Master Panel Valve diagram

HydroShark Master Panel Valve

Multi-zone systems with Master Panel and zoning by valve

When a Thermostat calls for heat, the HydroShark® Boiler fires (if necessary), and the Boiler Pump moves the heated fluid around the primary loop. Heat transfers to the secondary emitter circuit via the Closely Spaced Tee.

The System Pump on the Master Panel circulates the heated fluid to the Zone Valves on the Zone Valve Panel. Each Zone Valve is paired with its associated Thermostat. Once the Zone Valve is opened, the heated fluid is delivered to the Distribution Manifold.

The PEX Loops in each emitter circuit can be adjusted individually with their Distribution Manifold, which should have flow meters and on/off valves for filling, purging, and adjusting flow individually for each PEX Loop.

The Closely Spaced Tee allows the primary boiler loop and the secondary emitter loop (pex loop) to be hydraulically separated from each other. This allows the flow rates of each circuit to be set independently for optimum performance.

HydroShark Master Panel Valve Tech Specs